524 research outputs found

    Central corneal thickness in spectral-domain OCT and associations with ocular and systemic parameters

    Get PDF
    Background. Optical coherence tomography (OCT) allows quantitative analysis of the anterior segment of the eye with a noncontact examination. The aim of this study is to analyze associations of central corneal thickness (CCT) as measured by OCT with ocular and systemic cardiovascular parameters. Methods. A cross-sectional study of 734 persons was performed in a working age population. Only healthy eyes were included. A comprehensive ophthalmological examination including refraction, noncontact tonometry, and imaging of the anterior segment by SD-OCT was performed. In parallel, a broad range of systemic cardiovascular parameters were measured. Associations were analyzed using a generalized estimating equations&#039; model. Results. CCT measurements showed a significant association with corneal curvature and intraocular pressure: a thinner CCT was associated with a flatter cornea and with lower intraocular pressure (p < 0.001). Age was positively associated with CCT (p < 0.001); all other cardiovascular parameters were not associated. Conclusion. A thinner cornea is associated with a flatter surface and with lower intraocular pressure readings, while there are no independent associations with refraction and systemic cardiovascular parameters. Our findings highlight the value of SD-OCT CCT measurements as a standard tool in anterior segment analysis

    Memory difference control of unknown unstable fixed points: Drifting parameter conditions and delayed measurement

    Full text link
    Difference control schemes for controlling unstable fixed points become important if the exact position of the fixed point is unavailable or moving due to drifting parameters. We propose a memory difference control method for stabilization of a priori unknown unstable fixed points by introducing a memory term. If the amplitude of the control applied in the previous time step is added to the present control signal, fixed points with arbitrary Lyapunov numbers can be controlled. This method is also extended to compensate arbitrary time steps of measurement delay. We show that our method stabilizes orbits of the Chua circuit where ordinary difference control fails.Comment: 5 pages, 8 figures. See also chao-dyn/9810029 (Phys. Rev. E 70, 056225) and nlin.CD/0204031 (Phys. Rev. E 70, 046205

    Referral patterns of children with glaucoma and their caretakers in Northern Tanzania.

    Get PDF
    AIM: To describe the referral patterns of children with primary childhood glaucoma (PCG) or secondary childhood glaucoma (SCG) and their presenting symptoms in Northern Tanzania. METHODS: A retrospective observational study of children 0.48, better eye). Most of the children (60%) and their caretakers presented on their own initiative, while 24% were sent by different general health cadres and 16% by eye care professionals. Buphthalmos was the main symptom mentioned as a trigger for presentation. CONCLUSION: The study shows that most of the children presented late resulting in advanced stages of glaucoma at the time of initiation of treatment. The majority attended the referral eye department on their own initiative with buphthalmos being the most commonly described symptom. Awareness creation among caretakers of children, general health and eye care providers, ideally embedded in general child health promotion activities, is needed to increase and accelerate referrals

    Dirac Neutrino Dark Matter

    Full text link
    We investigate the possibility that dark matter is made of heavy Dirac neutrinos with mass in the range [O(1) GeV- a few TeV] and with suppressed but non-zero coupling to the Standard Model Z as well as a coupling to an additional Z' gauge boson. The first part of this paper provides a model-independent analysis for the relic density and direct detection in terms of four main parameters: the mass, the couplings to the Z, to the Z' and to the Higgs. These WIMP candidates arise naturally as Kaluza-Klein states in extra-dimensional models with extended electroweak gauge group SU(2)_L* SU(2)_R * U(1). They can be stable because of Kaluza-Klein parity or of other discrete symmetries related to baryon number for instance, or even, in the low mass and low coupling limits, just because of a phase-space-suppressed decay width. An interesting aspect of warped models is that the extra Z' typically couples only to the third generation, thus avoiding the usual experimental constraints. In the second part of the paper, we illustrate the situation in details in a warped GUT model.Comment: 35 pages, 25 figures; v2: JCAP version; presentation and plots improved, results unchange

    The impact of pseudophakia on vision-related quality of life in the general population -The Gutenberg Health Study

    Get PDF
    ABSTRACT Cataract surgery is the most frequently performed surgical procedure worldwide. We aim to determine the prevalence of having implanted an artificial lens (pseudophakia) and of no lens (aphakia) and to compare visual function. As part of the Gutenberg Health study, a population-based cross-sectional study was conducted in Germany. An ophthalmological examination including slit-lamp examination was conducted. Prevalence including 95% confidential intervals were calculated and analyses were conducted for systemic and ocular associated factors with pseudophakia using multivariable logistic regression models. Vision-related quality of life was assessed using a standardized questionnaire and Rasch transformation. 14,696 people were included. Of these, 1.55% [1.36%-1.77%] had unilateral pseudophakia and 3.08% [2.81%-3.37%] had bilateral pseudophakia. Unilateral aphakia was present in 21 people and bilateral aphakia in 2 people. Pseudophakia was independently associated with age, higher body weight and lower body height, diabetes and smoking. Vision-related quality of life values were similar for those with bilateral phakia and pseudophakia but were lower for those with unilateral pseudophakia. The pseudophakia status is related to several cardiovascular risk factors, indicating a relationship to an aging effect that causes premature lens opacification. Bilateral pseudophakia can almost imitate the physiological condition of phakia except for the need to use glasses

    Steeper Iris Conicity Is Related to a Shallower Anterior Chamber: The Gutenberg Health Study

    Get PDF
    Purpose. To report the distribution of iris conicity (steepness of the iris cone), investigate associated factors, and test whether pseudophakia allows the iris to sink back. Methods. A population-based cross-sectional study was carried out. Ophthalmological examination including objective refraction, biometry, noncontact tonometry, and Scheimpflug imaging (Pentacam®, Oculus) was performed including automated measurement of iris conicity. 3708 phakic subjects, 144 subjects with bilateral and 39 subjects with unilateral pseudophakia were included. Multivariable analyses were carried out to determine independently associated systemic and ocular factors for iris conicity in phakic eyes. Results. Mean iris conicity was 8.28° ± 3.29° (right eyes). Statistical analysis revealed associations between steeper iris conicity and shallower anterior chamber depth, thicker human lens and higher corneal power in multivariable analysis, while older age was related to a flatter iris conicity. Refraction, axial length, central corneal thickness, pupil diameter, and intraocular pressure were not associated with iris conicity. Pseudophakia resulted in a 5.82° flatter iris conicity than in the fellow phakic eyes. Conclusions. Associations indicate a correlation between iris conicity with risk factors for angle-closure, namely, shallower anterior chamber depth and thicker human lens. In pseudophakic eyes, iris conicity is significantly lower, indicating that cataract surgery flattens the iris

    Multifractals of Normalized First Passage Time in Sierpinski Gasket

    Full text link
    The multifractal behavior of the normalized first passage time is investigated on the two dimensional Sierpinski gasket with both absorbing and reflecting barriers. The normalized first passage time for Sinai model and the logistic model to arrive at the absorbing barrier after starting from an arbitrary site, especially obtained by the calculation via the Monte Carlo simulation, is discussed numerically. The generalized dimension and the spectrum are also estimated from the distribution of the normalized first passage time, and compared with the results on the finitely square lattice.Comment: 10 pages, Latex, with 3 figures and 1 table. to be published in J. Phys. Soc. Jpn. Vol.67(1998

    Prevalence of depression and anxiety among participants with glaucoma in a population-based cohort study : the Gutenberg Health Study

    Get PDF
    Background To investigate the prevalence of depression and anxiety among subjects with self-reported glaucoma and the association between self-reported glaucoma and depression respectively anxiety in a European cohort. Methods A study sample of 14,657 participants aged 35 to 74 years was investigated in a population-based cohort study. All participants reported presence or absence of glaucoma. Ophthalmological examinations were carried out in all participants and demographic and disease related information were obtained by interview. Depression was assessed with the Patient Health Questionnaire (PHQ-9), and generalized anxiety with the two screening items (GAD-2) of the short form of the GAD-7 (Generalized Anxiety Disorder-7 Scale). Prevalence of depression and generalized anxiety were investigated for subjects with and without self-reported glaucoma. Logistic regression analyses with depression, respectively anxiety as dependent variable and self-reported glaucoma as independent variable were conducted and adjusted for socio-demographic factors, systemic comorbidities (arterial hypertension, myocardial infarction, stroke, diabetes mellitus, chronic obstructive pulmonary disease, cancer), ocular diseases (cataract, macular degeneration, corneal diseases, diabetic retinopathy), visual acuity, intraocular pressure, antiglaucoma eye drops (sympathomimetics, parasympathomimetics, carbonic anhydrase inhibitors, beta-blockers, prostaglandins) and general health status. Results 293 participants (49.5% female) reported having glaucoma. Prevalence of depression among participants with and without self-reported glaucoma was 6.6% (95%-CI 4.1–10.3) respectively 7.7% (95%-CI 7.3–8.2), and for anxiety 5.3% (95%-CI 3.1–8.7) respectively 6.6% (95%-CI 6.2–7.1). Glaucoma was not associated with depression (Odds ratio 1.10, 95%-CI 0.50–2.38, p = 0.80) or anxiety (1.48, 95%-CI 0.63–3.30, p = 0.35) after adjustment for socio-demographic factors, ocular/systemic diseases, ocular parameters, antiglaucoma drugs and general health status. A restriction to self-reported glaucoma cases either taking topical antiglaucoma medications or having a history of glaucoma surgery did not alter the result. Conclusions This is the first study analyzing both depression and anxiety among glaucoma patients in a European cohort. Subjects with and without self-reported glaucoma had a similar prevalence of depression and anxiety in our population-based sample. Self-reported glaucoma was not associated with depression or anxiety. A lack of a burden of depressive symptoms may result from recruitment from a population-based sample as compared to previous study groups predominantly recruited from tertiary care hospitals

    Endemic fungal infections in solid organ and hematopoietic cell transplant recipients enrolled in the Transplant‐Associated Infection Surveillance Network ( TRANSNET )

    Full text link
    Background Invasive fungal infections are a major cause of morbidity and mortality among solid organ transplant ( SOT ) and hematopoietic cell transplant ( HCT ) recipients, but few data have been reported on the epidemiology of endemic fungal infections in these populations. Methods Fifteen institutions belonging to the Transplant‐Associated Infection Surveillance Network prospectively enrolled SOT and HCT recipients with histoplasmosis, blastomycosis, or coccidioidomycosis occurring between March 2001 and March 2006. Results A total of 70 patients (64 SOT recipients and 6 HCT recipients) had infection with an endemic mycosis, including 52 with histoplasmosis, 9 with blastomycosis, and 9 with coccidioidomycosis. The 12‐month cumulative incidence rate among SOT recipients for histoplasmosis was 0.102%. Occurrence of infection was bimodal; 28 (40%) infections occurred in the first 6 months post transplantation, and 24 (34%) occurred between 2 and 11 years post transplantation. Three patients were documented to have acquired infection from the donor organ. Seven SOT recipients with histoplasmosis and 3 with coccidioidomycosis died (16%); no HCT recipient died. Conclusions This 5‐year multicenter prospective surveillance study found that endemic mycoses occur uncommonly in SOT and HCT recipients, and that the period at risk extends for years after transplantation.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/106980/1/tid12186.pd
    corecore